Technical parameters
Rhino Sensor – AQM is an air quality meter. It measures air temperature and/or humidity, PM2.5 and PMTO concentrations, as well as air quality (VOCt and CO₂). Data transfer is wireless via RF to the Rhino AP. Rhino ED RS485 is powered by an external 5-12VDC power supply.
REQUEST A QUOTE
Technical parameters
Rhino communication | Frequency range: 433MHz, ISM 1 channel |
Power supply | 5-12VDC (0.2A) |
Temperature Sensor | Range -40 ℃ – 85 ℃ Accuracy 0.5 ℃ |
Humidity sensor | Range 0% – 100% – 25 ℃ (without moisture condensing inside the device) Accuracy 3% |
CO₂ VOCt levels | Air quality indicator with at least three levels: poor / moderate / good |
PM1.0, PM2.5 and PM10 levels | Range: 0.3 – 1 μm PM 1 / 1 – 2.5 μm PM 2.5 / 2.5 – 10 μm PM 10 Measuring range: 0 – 500 μm Measurement accuracy: ±10% van 100 tot 500 μg/m³ ±10μ g/m³ van 0 tot 500 μg/m³ |
Configuration | Over the Air (OTA) |
perating temperature range | -40 ℃ – 85 ℃ (depending upon installed environment) -10 ℃ – 60 ℃ (with particle concentration sensor) |
IP class | IP42 (double insulated) |
Dimensions | 102 mm x 160 mm x 55.5 mm |
Weight | ~0.3kg |
Additional equipment | 1 x ISM antenna with 3m cable and magnetic base |
Required cable types | Signal thickness – 0.129-1.31 MM² – 26-16AWG Power supply thickness – 0.205-3.31 MM² – 24-12AWG |